    Comfort heating solutions for upgrading bathroom
    Heating cable bathroom low-temperature radiant heating consist of heating cable under the floor materials and electronic thermostat auto-regulate temperature. Rising hot air flow ensure quantity of heat well-distributed and optimal hot comfort. The system combines the optimal comfort, maximum regulation with minimum energy consumption. The high-quality products let you buy without concern over quality, high-tech electronic thermostat reassure you to use it. It only needs 5 mm
 
Floor Heating
  •Introduction
  •Development Advantages
  •System Merits
  •Application Field
  •Synthetically Comparing
  •Cost Comparing
  •Example
 
Pipeline Heat Preservation
  •Introduction
  •System Merits
  •Application Field
  •Example
 
Bathroom Upgrading Solutions
  •Advantages Introduction
  •Solutions
  •Specification of Products
 
Other Outdoor Applications
  •Eaves and Furrow Snow Melting
  •Road Snow Melting
  •Soil Heating
  installation height to change your floor materials. We provide you individual design solutions for any room dimension, whatever it is 1~2m limited bathroom space, or other any size room and lobby.

     1. System Merits
    Optimal comfort
    Heat transmission of the ordinary heating system is: hot air flow rise to the ceiling, then back to the air conditioning area after air flow temperature reduce. Quantity of heat of bathroom floor radiant heating system is well-distributed in the whole floor surface -- hot air from bottom to top is the optimal indoor heat quantity distribution and transmission. Science proves that human body feel the most comfortable when the foot temperature is 3 ~ 5¡æ higher than the head temperature.

    Latent system -- Feel its "warm" but can't see its "source"
    Heating cable bathroom low temperature radiant heating system is under the floor materials--The latent heat source provide plenty of convenience and complete freedom for house decorating design. It make you not suffer the discomfort brought from dryness, noise, arrange airflow, It is the most ideal products choice of children, old people, hypersensitivity, respiratory track disease patient.

    Original investment low
    Bathroom heating system price is equal to high-quality carpet or marble floor price one with same area, Can make you have highest comfortable degree, and no longer need other heating systems.

    The most economical operation expenses:
    From operation cost weigh, heating cable bathroom low-temperature radiant heating system is extremely attractive and competitive. Position of heat source under floor, accurate electronic thermostat guarantee high-level energy utilization (accurate to 0.1¡æ) and that is to say, You can reduce about 20% of the energy to lose ----Not only save the electric rate for you but also favorable to the ecological environment.

    Wide application scope:
    Aluminium foil heating cable suitable for all kinds of bathroom, suitable for install on newly-built building concrete layer especially, the building does not highly play a decisive role to the heating result. At the time of choosing the best scheme of heat supply of the bathroom, advising you to get in touch with our authorized distributor to offer help to you.

    Simple, direct and convenient to install:
    The installation of bathroom hot floor radiant heating system is simple and direct and fast. aluminium foil heating cable lay at ground directly, fix it well, install sensor, casting cement layer, then spread the floor brick.

    10 years Guarantee period
    The heating cable bathroom low temperature radiant heating system has already got supreme quality authentication of a lot of countries. The all users of cable floor heating systems have the warranty period of 10 years

    2. Accessory directions
    a. One 2m long ¦Õ 12 hose, used for pull on the sensor wire of thermostat
    b. One thermostat with sensor
    c. One leakage protector, install it in the distribution case indoors
    3. Installation steps direction:
    a. Measure the size of the bathroom and hygiene utensil, draw sketch maps, computing the system power briefly, Mark the heating cable arrangement drawing, and the position of thermostat and sensor.
    b. Cable should try one's best distributing spacious ground in room even, wind drain pipe, water pipe and other of clean basin enclosed and connected with the facility on the ground , In case that damage the cable while coming to house ornamentation to maintain
    c. Clear up and get ground ready , heating aluminium foil cable tile and fix at grass ground
    d. Penetrate sensor line on the hose and put sensor in the centre position of the aluminium foil laid , Sensor holds up inviting 50mm crookedly upwards. The sensor hose extreme point of sensor uses the rubberized fabric or the glue to be sealed, in order to prevent the cement or the concrete from entering the hose, Cause sensor sensing not to work.
    e. Reserve position install thermostat, from about 1.5, thermostat and sensor line should reliable hookup at wall
    f. After the cable aluminium foil is installed, be sure to measure the resistance value, the size of resistance value should keep the same with marking on the label , Allow 5% --10% of the errors.
    g. With flow automatically flat cement or other floor adhesive cover aluminium foil heating cable
    h. Lay the floor brick. Finish installing
    4. Directions of thermostat
    a. Install flexible position , but should try one's best to be far away from water equipment , so as not to be made moist and does not work
    b. Temperature is adjustable, easy to use
    c. With the reliable hookup of sensor, pay attention to preventing the cement or the concrete from entering the hose when sensor wears the hose
    d. Heating cable regulates thermostat a lower temperature scale when not using in a short time, Intensify fast while soing as to ensure that will start next time; When not using for a long time, disconnection leaks electricity and protects the switch
    5. The precautions explaining
    a. Must be authorized the electrician to carry out with the hookup of the arterial power, installing must be carried out by the professional personnel
    b. Use inalienably , must guarantee the integrality of the cable that the aluminium foil generates heat
    c. Large area bathroom need many pieces of aluminium foil on generating heat cable, mutual lead wire link and take reliable
    d. Can't nail or other sharp article at ground, so as not to damage cable lead to the fact the short circuit

    Is the system expensive?
    One square meter of intact heating cable bathroom low-temperature radiation price of heating systems equate high-quality carpet or marble floor with. You have highest comfortable degree, no longer need other heating systems.

    Is the power consumption expensive?
    The energy consumption depends on a lot of factors, for instance the standards of the building, such as the window and thermal insulator,etc.; The heat released from the human body, the sun, requisition on comfortable degrees of people,etc.. In other words, it is compensating according to the need for living in the person in the room that the heat of the room is lost. Undoubtedly one point, namely through generate heat each room cable bathroom low-temperature radiation heating system heats and has not transmitted lossing ----You can choose to heat some rooms of yours , for example the bathroom heats it is heated that it is independent of other rooms. Energy efficiency is the most ideal ----One coin paid, one coin gains. According to experience, use current building criterion, the energy consumption of the area in China Shanghai is probably: 60-90 degrees / m2/ are annual. Because the consumption of energy depends on many kinds of factors, your local concrete energy consumption , Please contact local authorized cooperative partner.

 